Schools are responsible for providing a safe environment for pupils, teachers, support staff, visitors and contractors. Emergency lighting is an important part of that responsibility because it helps people safely navigate escape routes if normal lighting fails. For schools reviewing their emergency lighting arrangements, William Hale Fire & Security can provide specialist support with emergency lighting inspection, testing and maintenance.
Emergency lighting compliance is not simply about checking whether lights switch on during a power failure. A compliant system needs to be appropriately designed, correctly positioned, regularly tested and properly maintained. Schools also need to keep suitable records and address faults when they are identified.
This checklist explains the main areas schools should consider when reviewing emergency lighting arrangements.
School Emergency Lighting Compliance Checklist
The following checklist provides a useful starting point for schools, academies, colleges and other educational premises.
| Compliance area | What should be checked? |
|---|---|
| Emergency lighting system | Is the system appropriate for the building and its current use? |
| Escape routes | Are relevant escape routes adequately illuminated? |
| Emergency exits | Are exits clearly identifiable during a power failure? |
| Staircases | Are stairs and changes in level adequately illuminated? |
| Exit signs | Are signs visible, correctly positioned and maintained? |
| Fire equipment | Can relevant fire safety equipment be located during an emergency? |
| Testing | Are required functional tests being completed? |
| Duration testing | Is the system periodically tested for the required duration? |
| Batteries | Are batteries performing correctly? |
| Luminaires | Are fittings free from damage and defects? |
| Records | Are test and maintenance records being retained? |
| Building alterations | Has the system been reviewed following changes? |
| Faults | Are identified defects being repaired promptly? |
| Professional maintenance | Is the system being inspected by competent personnel? |
The exact requirements for a particular school depend on its design, occupancy, escape arrangements, risk assessment and applicable standards.
1. Check Whether the School Has Appropriate Emergency Lighting
The first step is to establish exactly what emergency lighting is installed throughout the premises.
A school may have emergency lighting covering corridors, staircases, halls, classrooms, exits and other areas. However, the system should reflect the building as it is currently used.
This is particularly important in older schools.
Buildings can change significantly over time. Classrooms may be combined, walls moved, extensions added and rooms converted for different purposes.
An emergency lighting system that was designed many years ago may therefore need to be reassessed.
Start by establishing:
- What emergency lighting is installed?
- Which areas are covered?
- Where are the emergency exits?
- What are the designated escape routes?
- When was the system last inspected?
- Have there been any significant building alterations?
- Are there outstanding faults?
- Are current drawings or system records available?
Having this information provides a useful starting point for assessing the condition of the installation.
2. Check All Relevant Escape Routes
Emergency lighting should support safe evacuation.
Walk through the school’s designated escape routes and consider what would happen if normal lighting suddenly failed.
This should include:
- Main corridors
- Secondary corridors
- Staircases
- Junctions
- Changes of direction
- Exit routes
- Areas where routes narrow
- Changes in floor level
- Areas leading towards final exits
The aim is to ensure that people can identify and follow the intended escape route even when normal lighting is unavailable.
This is especially important in schools because pupils may not always be familiar with every part of the building.
3. Check Staircases Carefully
Staircases should receive particular attention during an emergency lighting inspection.
A loss of normal lighting can make steps difficult to see, increasing the risk of trips and falls during evacuation.
Check whether emergency lighting adequately illuminates relevant stairways and makes changes in level visible.
This includes:
- Main staircases
- Secondary staircases
- Fire escape stairs
- Changes in floor level
- Landings
- Areas where stairs meet corridors
A staircase that appears perfectly safe during normal daylight conditions can become significantly more hazardous in darkness.
4. Inspect Emergency Exit Signs
Emergency exit signs help people identify where they should leave the building.
Check each relevant sign for:
- Correct positioning
- Visibility
- Damage
- Obstructions
- Illumination
- Correct directional information
- Consistency with the school’s current escape routes
A sign may be physically present but still fail to provide useful information if it is obscured by a new partition, damaged or no longer points towards the appropriate route.
Building alterations should therefore trigger a review of emergency signage.
5. Check Emergency Lighting at Final Exits
The route does not end when someone reaches the final door.
People need to be able to identify the final exit and safely move away from the building.
Check that relevant final exits are appropriately identified and that the surrounding arrangements support safe evacuation.
External areas may also need consideration depending on the school’s layout and escape strategy.
For example, a school may have a final exit leading onto a path that continues around the side of the building. The emergency lighting design needs to consider the circumstances of that escape route rather than stopping at the doorway.
6. Check Fire-Fighting Equipment Locations
Emergency lighting can also help people locate important safety equipment during an emergency.
Relevant locations may include:
- Fire extinguishers
- Fire alarm call points
- Fire blankets
- Other fire safety equipment
The purpose is not to encourage untrained people to fight a fire instead of evacuating. Rather, appropriate illumination can help occupants identify important safety equipment and information when visibility is reduced.
The emergency lighting design should take the relevant requirements into account.
7. Check Assembly and Large Occupancy Areas
Schools often contain large rooms that may be used by substantial numbers of people.
Examples include:
- Assembly halls
- Sports halls
- Dining halls
- Performance spaces
- Multi-purpose rooms
- Large classrooms
These areas should be considered as part of the emergency lighting assessment.
A large hall can present different evacuation challenges compared with a narrow corridor.
Furniture layouts, seating arrangements, multiple exits and changing room configurations can all affect how people move through the space.
If the use of a room has changed, the emergency lighting arrangements should be reviewed accordingly.
8. Confirm Regular Emergency Lighting Testing
Emergency lighting should be tested regularly.
A common maintenance arrangement includes regular functional testing, supported by periodic more detailed testing.
Testing helps establish whether the system will operate when required rather than simply assuming that the equipment remains functional because it was installed correctly.
A school should have a documented testing programme covering the emergency lighting installation.
Records should show:
- Date of test
- Areas or fittings tested
- Test result
- Faults identified
- Corrective action
- Date faults were repaired
- Person carrying out the work
The school’s maintenance arrangements should also take account of manufacturer’s instructions and relevant standards.
9. Check That Monthly Functional Tests Are Recorded
Regular functional tests can help identify obvious faults.
During a functional test, the normal lighting supply to the emergency lighting system is interrupted in an appropriate manner so that the emergency fittings can be checked.
The exact testing method depends on the installation.
After testing, emergency lighting should be allowed to recharge where necessary.
A common problem is carrying out tests without maintaining adequate records.
A school should be able to demonstrate when testing has taken place and whether any defects were identified.
A simple log can make this much easier.
| Date | Area tested | Result | Fault identified | Action taken |
|---|---|---|---|---|
| 1 September | Main corridor | Pass | None | None |
| 1 September | Staircase A | Pass | None | None |
| 1 September | Sports hall | Fault | One fitting failed | Repair arranged |
| 1 September | Upper corridor | Pass | None | None |
The exact format of the log can vary, but records should be clear and useful.
10. Carry Out Full-Duration Testing
Short functional tests do not demonstrate that emergency lighting batteries can operate for the required period.
Full-duration testing is therefore an important part of emergency lighting maintenance.
A system may switch on correctly but have batteries that have deteriorated to the point where they cannot maintain illumination for the required duration.
During a full-duration test, the emergency lighting system operates on its backup supply for the specified period.
The results should be recorded and any failures investigated.
Because this test can discharge batteries significantly, suitable arrangements need to be made to ensure that the building is not left without appropriate emergency lighting protection.
11. Inspect Emergency Lighting Batteries
Batteries are a critical part of many emergency lighting systems.
They provide the alternative power supply when normal electrical power is unavailable.
Battery performance can deteriorate over time.
Potential warning signs include:
- Reduced operating duration
- Repeated test failures
- Slow charging
- Visible damage
- Battery leakage
- Age-related deterioration
A battery that has reached the end of its useful service life may need to be replaced.
Schools should also ensure that replacement batteries are suitable for the relevant emergency lighting equipment.
12. Inspect Emergency Lighting Fittings
Emergency luminaires should be checked for visible damage and deterioration.
A school environment can be demanding for electrical equipment.
Fittings can be affected by:
- Accidental impacts
- Sports equipment
- Furniture movement
- Maintenance work
- Vandalism
- Dust
- Moisture
- General age
Check that fittings are securely mounted and free from obvious damage.
Where a fitting is damaged, it should be assessed by a competent person rather than simply being left in place.
13. Check Emergency Lighting Indicators
Many emergency lighting units have indicators showing the condition of the charging system or battery.
These indicators can provide useful information during routine inspections.
A warning indicator, unusual status or failed indicator should be investigated.
However, indicator lights should not be treated as a substitute for proper testing.
A green indicator does not necessarily prove that the battery will operate correctly for the required duration.
14. Check Exit Signs for Obstructions
Emergency signage needs to remain visible.
During a school inspection, look for anything that could obstruct an exit sign.
Potential obstructions include:
- New signage
- Displays
- Decorations
- Noticeboards
- Furniture
- Suspended decorations
- Temporary partitions
- Sports equipment
Schools can change rapidly, particularly during term time.
A corridor that was clear when the emergency lighting system was installed may contain additional displays or equipment several years later.
Routine visual checks can help identify these issues.
15. Review Emergency Lighting After Building Work
Any significant building alteration should trigger a review of emergency lighting.
This could include:
- New classrooms
- Extensions
- New partitions
- New corridors
- Changes to doors
- New staircases
- Refurbished halls
- Converted rooms
- Altered escape routes
Even apparently minor changes can affect how people move through the building.
For example, a new partition could alter the route through a corridor and change the visibility of an existing emergency exit sign.
Emergency lighting should therefore be considered whenever the school’s layout changes.
16. Check Emergency Lighting Against the Current Fire Risk Assessment
Emergency lighting should form part of the school’s wider fire safety arrangements.
The fire risk assessment should consider the building’s layout, occupancy, hazards, escape routes and relevant precautions.
If the fire risk assessment identifies a change in risk, the emergency lighting arrangements may also need to be reviewed.
Similarly, changes to emergency lighting should be reflected in relevant fire safety documentation where appropriate.
The objective is to ensure that the school’s different safety systems continue to work together.
17. Understand the Main Emergency Lighting Standards
Several standards and legal requirements may apply to emergency lighting in educational premises.
The Regulatory Reform (Fire Safety) Order 2005 is particularly important for fire safety duties in non-domestic premises in England.
BS 5266-1 provides guidance on emergency lighting systems, while BS EN 1838 covers lighting applications and emergency lighting performance. BS EN 50172 addresses emergency escape lighting systems.
There are also requirements and guidance relevant to the design and construction of educational buildings.
The exact requirements depend on the building and circumstances, so schools should avoid relying on a generic checklist as proof of compliance.
A checklist is useful for identifying areas requiring attention, but professional assessment may be necessary where the system is complex or significant deficiencies are suspected.
18. Check That Faults Are Being Repaired
Identifying a fault is only the first stage.
The fault needs to be appropriately investigated and rectified.
Common emergency lighting faults include:
| Fault | Possible issue |
|---|---|
| Light does not operate | Lamp, LED, battery, charging or electrical fault |
| Short operating time | Battery deterioration |
| Exit sign not illuminated | Power, battery or fitting fault |
| Indicator showing a fault | Charging or battery problem |
| Physical damage | Impact or deterioration |
| Multiple fittings failing | Possible circuit or common supply issue |
| Poor visibility | Positioning, obstruction or inadequate illumination |
The appropriate remedy depends on the cause.
Schools should avoid repeatedly resetting or replacing components without establishing why failures are occurring.
19. Keep Emergency Lighting Documentation Up to Date
Documentation is an important part of compliance management.
A well-maintained emergency lighting file should ideally contain relevant information such as:
- System details
- Installation information
- Inspection reports
- Testing records
- Full-duration test results
- Fault reports
- Repair records
- Battery replacement information
- Maintenance details
- Relevant drawings
- Certificates where applicable
Good records provide a history of the system and can make future inspections much easier.
They can also help a new facilities manager understand the maintenance history of the school.
20. Check Whether the System Is Suitable for LED Upgrades
Many older schools have emergency lighting systems containing older lamp technologies.
LED emergency lighting can offer advantages such as energy efficiency, long service life and reduced maintenance requirements.
However, replacing old fittings should not simply involve swapping one light for another without considering the emergency lighting design.
Changing fittings can affect:
- Light distribution
- Illumination levels
- Battery requirements
- Charging arrangements
- Compatibility
- Existing wiring
- System monitoring
- Emergency duration
Any upgrade should therefore be properly assessed and designed.
21. Consider School-Specific Risks
Schools have characteristics that can make emergency evacuation more complex.
The building may contain:
- Young children
- Large numbers of pupils
- Visitors
- Staff unfamiliar with certain areas
- Pupils requiring additional assistance
- Sports equipment
- Laboratories
- Kitchens
- Workshops
- Large assembly spaces
- Multiple buildings
Emergency lighting arrangements should support the school’s actual evacuation strategy.
For example, a secondary school with several interconnected buildings will have different considerations from a small primary school operating from a single building.
The same generic installation approach should not automatically be applied to every educational premises.
22. Check External Escape Areas Where Relevant
Emergency evacuation does not necessarily end immediately after someone passes through a final exit.
Some schools have external routes that people need to follow before reaching a safe assembly area.
These could include:
- Side paths
- Courtyards
- External stairways
- Covered walkways
- Service routes used as escape paths
Where such areas form part of the escape arrangement, their lighting should be considered as part of the overall emergency strategy.
23. Make Sure Staff Know the Emergency Lighting Arrangements
Emergency lighting is an engineering system, but staff awareness also matters.
Relevant staff should understand:
- Which areas are covered
- How testing is managed
- How faults are reported
- Who is responsible for arranging repairs
- Where maintenance records are kept
- What happens if a significant fault is discovered
Staff should also understand that emergency lighting supports evacuation but does not replace the school’s fire evacuation procedures.
24. Review Emergency Lighting Before the New School Year
The summer holiday can be a useful opportunity for schools to review building safety systems.
Schools are often quieter, making it easier to carry out maintenance without disrupting lessons.
A pre-term emergency lighting review can include:
- Checking maintenance records.
- Reviewing outstanding faults.
- Inspecting visible fittings.
- Checking exit signage.
- Reviewing recent building changes.
- Confirming testing arrangements.
- Checking battery condition.
- Reviewing fire risk assessment findings.
- Arranging remedial work.
- Updating records.
This can help ensure that the emergency lighting system is ready for the return of pupils and staff.
Emergency Lighting Compliance Checklist for School Managers
For a quick reference, the following checklist can be used as part of a wider maintenance programme.
| Check | Completed |
|---|---|
| Emergency lighting system identified | ☐ |
| Current escape routes reviewed | ☐ |
| Staircases checked | ☐ |
| Emergency exits checked | ☐ |
| Exit signs inspected | ☐ |
| Fire equipment locations considered | ☐ |
| Large halls and assembly areas reviewed | ☐ |
| Monthly testing programme in place | ☐ |
| Testing records maintained | ☐ |
| Full-duration testing completed when required | ☐ |
| Batteries checked | ☐ |
| Luminaires inspected | ☐ |
| Emergency lighting indicators checked | ☐ |
| Faults recorded | ☐ |
| Faults repaired | ☐ |
| Building alterations reviewed | ☐ |
| Fire risk assessment considered | ☐ |
| Maintenance records updated | ☐ |
| Competent inspection arranged where required | ☐ |
When Should a School Arrange Professional Emergency Lighting Maintenance?
Professional maintenance should form part of the school’s ongoing safety arrangements rather than being arranged only after a failure.
A specialist can assess the condition of the installation, carry out appropriate testing, identify faults and advise on remedial work.
Professional attention is particularly important where:
- The system is old
- Multiple fittings are failing
- Batteries repeatedly fail
- The building has recently been altered
- Escape routes have changed
- Existing records are incomplete
- The school is unsure when the system was last fully tested
- Emergency lighting has been installed across several extensions
- A fire risk assessment has identified concerns
- The system has not received regular professional maintenance
For educational premises, reliable emergency lighting is an important part of the wider fire safety strategy. Regular inspection, testing, maintenance and record keeping help schools identify problems before emergency lighting is actually needed, while a structured compliance checklist provides a practical way to keep the system under review.